You are being redirected to ABC Office. Why? has joined their sister company ABC Office to provide our customers with a greater product selection, while offering the same great prices and service you have come to love and expect!If you have questions or concerns during this transition please give us a call at 1-800-658-8788, or email us at sales@abcoffice.com.

| | FAQ | Help

Keyword Product Code

by Category


by Manufacturer


Siteseal
We Accept Company and Government Purchase Orders!


Item Price Lease to Own Price Quantity Add to Cart

13" Basic Kit


Condition: New

Item #: SHKSSS13MK

$13 Leasing Not Available

18" Basic Kit


Condition: New

Item #: SHKSSS18MK

Your Price: $15
Leasing Not Available

24" Basic Kit


Condition: New

Item #: SHKSSS24MK

$16 Leasing Not Available

32" Basic Kit


Condition: New

Item #: SHKSSS32MK

Your Price: $19
Leasing Not Available

40" Basic Kit


Condition: New

Item #: SHKSSS40MK

$21 Leasing Not Available

13" Complete Kit


Condition: New

Item #: SHKSSS13PK

$42 Leasing Not Available

18" Complete Kit


Condition: New

Item #: SHKSSS18PK

$45 Leasing Not Available

24" Complete Kit


Condition: New

Item #: SHKSSS24PK

$53 Leasing Not Available

32" Complete Kit


Condition: New

Item #: SHKSSS32PK

$60 Leasing Not Available

40" Complete Kit


Condition: New

Item #: SHKSSS40PK

$69 Leasing Not Available
Please contact us for quantity discounts, quotes or product availability.


Price Match Super Sealer Replacement Parts Kit Super Sealer Replacement Parts Kit Quote Request


Product Details


  • Basic Replacement Parts Kit Contains
  • 2 Each - 3 Mil Teflon Tape
  • 1 Each - 10 Mil Teflon Tape
  • 1 Each - Nichrome Wire with Connectors

  • Complete Replacement Parts Kit Contains
  • 1 Each - Silicone Rubber Sealing Pad
  • 5 Each - 3 Mil Teflon Tape
  • 3 Each - 10 Mil Teflon Tape
  • 1 Each - Nichrome Wire with Connectors
  • 1 Each - Micro Switch
  • 1 Each - Arm Spring and Anchor
  • 1 Each - Fuse

Basic Traco I-Bar Sealer Replacement Kit


Before replacing parts, please make sure the machine is turned off and unplugged.

Instructions for Changing Teflon Tape

  1. Remove old tape from the sealer's silicone pad (as shown in Figure 1.).
  2. Use rubbing alcohol and a clean cloth to clean the silicone pad. This will help the new Teflon tape to better adhere to the surface.
  3. Apply the 10 mil Teflon tape to the silicon pad (as shown in Figure 1.).
  4. Now you will want to remove the worn tape from the flexboard found on the bottom of the sealing arm. (shown in Figure 2.).
  5. If you notice any brown or yellow film or other burnt residue on the flexboard, you will need to scrape and wipe it off using a lightly damp cloth. If needed, you can also use fine-grain sandpaper to help remove burnt residue. Removing this burnt residue and film will allow the new tape to stick.
  6. If you need to replace the nichrome wire, please follow the instructions further down the page titled "Instructions for Replacing Nichrome Wire." As soon as the nichrome wire is changed, or if you are not changing the wire, please clean the existing wire using a cloth and rubbing alcohol. You can now apply the new piece of 3 mil Teflon tape to the flexboard and over the nichrome wire (as shown in Figure 2.).


Super Sealer Basic Replacement Parts Kit

Instructions for Replacing Nichrome Wire

  1. Remove the screw found on the right-side of the sealing arm. Now remove the black plastic endcap. Now remove the white colored insulator sleeve. You will now need to find the bolt, nut and spring. You can now remove the assembly from the arm slot by pulling downwards. (You may need to use a flathead screwdriver to pry it loose) (as shown in Figure 2.).
  2. You will now want to loosen and remove the first nut found on the bolt that runs through the insulator. Doing this should help to release the upper end of the sealing wire.
  3. You will now need to find the access hole that is found on the bottom base. Take the sealing arm, hold it down and loosen the screw. (PLEASE DO NOT REMOVE THE SCREW. YOU ONLY NEED TO LOOSEN IT A FEW TURNS). You can now remove the sealing wire. Attach and hook the new wire under the screw and tighten it back down. Be sure the new wire is properly aligned.
  4. You can now re-attach the wire to the bolt found on the front of the sealing arm. Place the ring terminal on the bolt and tighten the nut back onto the bolt. You will now want to slide the insulator back into the slot found on the sealing arm making sure the flat side of the insulator is facing toward the arm. You can now tighten the first nut until it is tight (DO NOT OVER TIGHTEN AS THIS MAY STRIP THE THREADS). You will now want to make sure the terminal is clamped tightly between the two nuts. Inspect the job and make any necessary adjustments.


Technical Details


Super Sealer Replacement Parts Kit
Model:SS13MK SS18MK SS24MK SS32MK SS40MK


Super Sealer Replacement Parts Kit
Model:SS13PK SS18PK SS24PK SS32PK SS40PK



800-658-8788 Local Phone: 801.927.3020 Fax Number: 801.927.3037

8:00am - 5:00pm (MST) M-F

Email ABC Office
Company Info ABC Office Blog ABC Office Facebook Page ABC Office Google+ Page
Home   |   Site Map   |   About Us   |   Contact Us   |   Policies 39 ABC Office YEARS Site Secured by Godaddy.com All Major Credit Cards Welcome! ShopSite Cart Amazon Star Rating